Error Code
Message Information
MEM1012
Message
Memory device at location <
location
> is in a degraded state.
Details
The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM1016
Message
Memory device at location <
location
> is not installed correctly.
LCD Message
Memory <
location
> is not installed correctly. Reinstall.
Details
The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory modules. If the
issue persists, see
MEM1205
Message
Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
LCD Message
Memory mirror lost on <
location
>. Power cycle system.
Details
The memory may not be seated correctly, misconfigured, or has
failed.
Action
Check the memory configuration. Re-seat the memory modules. If the
issue persists, see
MEM1206
Message
Memory mirror redundancy is degraded. Check memory device at
location <
location
>.
Details
The memory may not be seated correctly, misconfigured, or has
failed.
Action
Check the memory configuration. Re-seat the memory modules. If the
issue persists, see
MEM1208
Message
Memory spare redundancy is lost. Check memory device at location
<
location
>.
LCD Message
Memory spare lost on <
location
>. Power cycle system.
Details
Memory sparing is no longer available.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM1212
Message
Memory redundancy is lost.
Details
The memory may not be seated correctly, misconfigured, or has
failed.