Dell PowerEdge VRTX User Manual
Page 129
Error Code
Message Information
LCD Message
System inlet <
name
> temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
TMP0122
Message
The system inlet temperature is outside of range.
LCD Message
System inlet <
name
> temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or cool.
Action
Check the system operating environment and review event log for fan
failures.
TMP0100
Message
Disk drive bay temperature is less than the lower warning threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0104
Message
Disk drive bay temperature is less than the lower critical threshold.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0126
Message
Disk drive bay temperature is greater than the upper warning
threshold.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
TMP0128
Message
Disk drive bay temperature is outside of the allowable range.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or cool.
Action
Check the system operating environment and review event log for fan
failures.
129