Dell PowerEdge VRTX User Manual
Page 81

Error Code
Message Information
Details
The system board battery is either missing, bad, or unable to charge
due to thermal issues.
Action
Check system fans. Replace the system board battery.
BAT0002
Message
The system board battery has failed.
LCD Message
The system board battery has failed. Check battery.
Details
The system board battery is either missing or bad.
Action
BAT0004
Message
The system board battery is absent.
LCD Message
The system board battery is absent. Check battery.
Action
Reinstall the system board battery.
BAT0005
Message
The storage battery is low.
Details
System has to remain powered on to charge the battery.
Action
Allow the battery to charge. If the issue persists, see
.
BAT0007
Message
The storage battery has failed.
LCD Message
The storage battery has failed. Check battery.
Details
Verify the cable connection between the storage battery and the
controller.
Action
Verify the storage battery installation.
BAT0010
Message
The storage battery for disk drive bay <
bay
> is low.
Details
System has to remain powered on to charge the storage battery.
Action
Allow the storage battery to charge. If the issue persists, see
.
BAT0012
Message
The storage battery for disk drive bay <
bay
> has failed.
LCD Message
Battery for disk drive bay <
bay
> has failed. Check battery.
Details
Verify the cable connection between the storage battery and the
controller.
Action
Verify the storage battery installation.
BAT0014
Message
The storage battery for disk drive bay <
bay
> is absent.
81