Dell PowerEdge VRTX User Manual
Page 91
Error Code
Message Information
Action
If removal was unintended, check presence, then reinstall or
reconnect.
HWC2006
Message
The <
name
> is not installed correctly.
LCD Message
The <
name
> is not installed correctly. Check connection.
Details
The device may be necessary for proper operation. System
functionality may be degraded.
Action
Check presence, then re-install or reconnect.
HWC2008
Message
A fabric mismatch detected between IOM and PCIe mezzanine card
<
number
>.
Details
The fabric type for the IOM and PCIe mezzanine cards must match.
Action
Check chassis fabric type in CMC GUI and compare to the type of
IOM or PCIe mezzanine card.
HWC2011
Message
The riser board cable or interconnect is not connected, or is
improperly connected.
LCD Message
Riser board cable or interconnect failure. Check connection.
Details
The riser server module cable may be necessary for proper
operation. System functionality may be degraded.
Action
Check the riser board or interconnect presence, then reinstall or
reconnect.
HWC3000
Message
The <
name
> is removed.
Details
The removed device may be necessary for proper operation. System
functionality may be degraded.
Action
If removal was unintended, check presence of the removed device,
then reinstall or reconnect
HWC3002
Message
Server <
number
> is removed.
Action
If removal was unintended, check presence of the server, then
reinsert.
HWC3004
Message
IO module <
number
> is removed.
Action
If removal was unintended, check presence of the IO module, then
reinsert.
91