Error Code
Message Information
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue persists,
see
.
PDR1024
Message
Drive mismatch detected for drive <
number
> in disk drive bay <
bay
>.
LCD Message
Drive mismatch detected for drive <
number
> in bay <
bay
>. Install
correct drive type.
Details
The installed disk does not meet the array requirements, for example
a SATA disk may not operate in an array containing SAS drives.
Action
Verify that the disk meets the array requirements.
PST0128
Message
No memory is detected.
LCD Message
No memory is detected. Inspect memory devices.
Details
System BIOS was unable to detect memory in the system .
Action
Re-seat the memory modules. If the issue persists, see
.
PST0129
Message
Memory is detected, but is not configurable.
LCD Message
Memory is detected, but is not configurable. Check memory devices.
Details
System BIOS detected memory, but was unable to configure the
memory for system operation.
Action
Compare system memory installation to supported system memory
configurations.
PST0130
Message
Memory is configured, but not usable.
LCD Message
Memory is configured, but not usable. Check memory devices
Details
The system BIOS encountered device failures or speed
configurations that resulted in unused memory.
Action
Re-seat the memory modules. If the issue persists, see
.
PST0131
Message
System BIOS shadow failed.
LCD Message
System BIOS shadow failed. Check memory devices.
Details
Memory errors occurred copying BIOS image into system memory.
Action
Remove input power. Reduce system memory to minimum
configuration and apply input power.
107