beautypg.com

Dell PowerEdge VRTX User Manual

Page 107

background image

Error Code

Message Information

Details

The controller detected that the drive was removed.

Action

Verify drive installation. Re-seat the failed drive. If the issue persists,
see

Getting Help

.

PDR1024

Message

Drive mismatch detected for drive <

number

> in disk drive bay <

bay

>.

LCD Message

Drive mismatch detected for drive <

number

> in bay <

bay

>. Install

correct drive type.

Details

The installed disk does not meet the array requirements, for example
a SATA disk may not operate in an array containing SAS drives.

Action

Verify that the disk meets the array requirements.

PST0128

Message

No memory is detected.

LCD Message

No memory is detected. Inspect memory devices.

Details

System BIOS was unable to detect memory in the system .

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0129

Message

Memory is detected, but is not configurable.

LCD Message

Memory is detected, but is not configurable. Check memory devices.

Details

System BIOS detected memory, but was unable to configure the
memory for system operation.

Action

Compare system memory installation to supported system memory
configurations.

PST0130

Message

Memory is configured, but not usable.

LCD Message

Memory is configured, but not usable. Check memory devices

Details

The system BIOS encountered device failures or speed
configurations that resulted in unused memory.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0131

Message

System BIOS shadow failed.

LCD Message

System BIOS shadow failed. Check memory devices.

Details

Memory errors occurred copying BIOS image into system memory.

Action

Remove input power. Reduce system memory to minimum
configuration and apply input power.

107