Error Code
Message Information
Details
The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Action
Check the event log for power supply failures. Review system
configuration and power consumption.
PWR1001
Message
The system performance was degraded.
LCD Message
System performance degraded. Check PSUs and system
configuration.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1002
Message
The system performance degraded because of thermal protection.
Details
To avoid shutdown, system performance has been degraded.
Action
Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1003
Message
The system performance degraded because cooling capacity has
changed.
Details
The current power supply configuration does not meet the platform
requirements to enable redundancy. If a power supply fails the
system may shutdown.
Action
If unintended, review system configuration and power consumption
and install power supplies accordingly. Check power supply status
for failures.
PWR1004
Message
The system performance degraded because power capacity has
changed.
Details
The system may power down or operate in a performance degraded
state.
Action
Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
PWR1005
Message
The system performance degraded because the user-defined power
capacity has changed.
Details
The user-defined power settings have affected system operation.