Dell PowerEdge VRTX User Manual
Page 105

Error Code
Message Information
Details
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and
does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, LOM, and PCIe mezzanine card firmware.
If the issue persists, see
PCI3004
Message
Device option ROM on PCIe mezzanine card <
number
> failed to
support Link Tuning or FlexAddress.
Details
Either the BIOS, BMC/iDRAC, or PCIe mezzanine card firmware is out
of date and does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, and PCIe mezzanine card firmware. If the
issue persists, see
PCI3006
Message
Failed to get Link Tuning or FlexAddress data from iDRAC.
Details
Either the BIOS or BMC/iDRAC firmware is out of date and does not
support FlexAddress.
Action
Update BIOS, and BMC/iDRAC firmware. If the issue persists, see
PCI3008
Message
A non-fatal PCIe error detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
PCI3010
Message
A non-fatal IO error detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
PCI3012
Message
The QuickPath Interconnect (QPI) width degraded.
Details
System performance may be degraded. The bus is not operating at
maximum speed or width.
Action
Reset the system, if the problem persists reinstall processors.
PCI3014
Message
A non-fatal PCIe error detected on a component at slot <
number
>.
Details
System performance may be degraded.