Dell PowerVault DP500 User Manual
Page 10

Invalid NVRAM configuration, Resource Re-
allocated
System detected and corrected a resource
conflict.
No action is required.
Keyboard Controller failure
Faulty keyboard controller; faulty system board
See
Getting Help
.
Manufacturing mode detected
System is in manufacturing mode.
Reboot to take the system out of manufacturing mode.
MEMBIST failure - The following DIMM/rank
has been disabled by BIOS: DIMM x Rank y
Faulty memory module(s).
See
Troubleshooting System Memory
.
Memory address line failure at address,
read value expecting value
Faulty or improperly installed memory modules.
See
Troubleshooting System Memory
.
Memory double word logic failure at
address, read value expecting value
Memory odd/even logic failure at address,
read value expecting value
Memory write/read failure at address, read
value expecting value
Memory tests terminated by keystroke.
POST memory test terminated by pressing the
spacebar.
Information only.
No boot device available
Faulty or missing optical/diskette drive
subsystem, hard drive, or hard-drive subsystem,
or no boot disk in drive A.
Use a bootable diskette, CD, or hard drive. If the problem
persists, see
Troubleshooting a Diskette Drive
,
Troubleshooting an Optical Drive
, and
Troubleshooting a
Hard Drive
. See
Using the System Setup Program
for
information on setting the order of boot devices.
No boot sector on hard drive
Incorrect configuration settings in System Setup
program, or no operating system on hard drive.
Check the hard-drive configuration settings in the System
Setup program. See
Using the System Setup Program
. If
necessary, install the operating system on your hard
drive. See your operating system documentation.
No timer tick interrupt
Faulty system board.
See "
Getting Help
."
Northbound merge error - The following
DIMM has been disabled by BIOS: DIMM x
The specified DIMM was unable to establish a
successful data link with the memory controller.
See
Troubleshooting System Memory
.
Not a boot diskette
No operating system on diskette.
Use a bootable diskette.
PCIe Degraded Link Width Error: Embedded
Bus#nn/Dev#nn/Funcn
Expected Link Width is n
Actual Link Width is n
Faulty or improperly installed PCIe card in the
specified slot.
Reseat the PCIe card in the specified slot number. See
Expansion Cards
. If the problem persists, see
Getting
Help
.
PCIe Degraded Link Width Error: Slot n
Expected Link Width is n
Actual Link Width is n
Faulty or improperly installed PCIe card in the
specified slot.
Reseat the PCIe card in the specified slot number. See
Expansion Cards
. If the problem persists, see
Getting
Help
.
PCIe Training Error: Embedded
Bus#nn/Dev#nn/Funcn
PCIe Training Error: Slot n
Faulty or improperly installed PCIe card in the
specified slot.
Reseat the PCIe card in the specified slot number. See
Expansion Cards
. If the problem persists, see
Getting
Help
.
PCI BIOS failed to install
PCI device BIOS (Option ROM) checksum failure
is detected during shadowing.
Loose cables to expansion card(s); faulty or
improperly installed expansion card(s).
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see
Troubleshooting Expansion
Cards
.
Plug & Play Configuration Error
Error encountered in initializing PCI device;
faulty system board.
Install the NVRAM_CLR jumper and reboot the system.
See
Figure 6
-1
for jumper location. If the problem
persists, see
Troubleshooting Expansion Cards
.
Read fault
Requested sector not found
The operating system cannot read from the
diskette or hard drive, the system could not find
a particular sector on the disk, or the requested
sector is defective.
Replace the diskette. Ensure that the diskette and hard
drive cables are properly connected. See
Troubleshooting
a USB Device
, or
Troubleshooting a Hard Drive
for the
appropriate drive(s) installed in your system.
Remote configuration update attempt failed
System unable to process Remote Configuration
request
Retry Remote Configuration.
ROM bad checksum = address
Expansion card improperly installed or faulty.
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see
Troubleshooting Expansion
Cards
.
Sector not found
Seek error
Seek operation failed
Faulty diskette or hard drive.
See
Troubleshooting a Diskette Drive
,
Troubleshooting a
USB Device
, or
Troubleshooting a Hard Drive
for the
appropriate drive(s) installed in your system.
Shutdown failure
Shutdown test failure.
See
Troubleshooting System Memory
.
The amount of system memory has changed
Memory has been added or removed or a
memory module may be faulty.
If memory has been added or removed, this message is
informative and can be ignored. If memory has not been
added or removed, check the SEL to determine if single-
bit or multi-bit errors were detected and replace the
faulty memory module. See
Troubleshooting System
Memory
.
Time-of-day clock stopped
Faulty battery or faulty chip.
See
Troubleshooting the System Battery
.
The following DIMM pair is not compatible
The specified DIMM(s) are incompatible with the
Ensure that only Dell-qualified memory is used. Dell