Dell PowerEdge R815 User Manual
Page 46
46
About Your System
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
page 53. If the problem
persists, replace the system
battery. See "System Battery"
Timer chip
counter 2 failed.
Faulty system board.
TPM or TCM
configuration
operation
honored. System
will now reset.
A Trusted Platform Module
(TPM) or China Trusted
Platform Module (TCM)
configuration command has
been entered. The system
will reboot and execute the
command.
Information only.
Message
Causes
Corrective Actions
book.book Page 46 Wednesday, December 18, 2013 2:48 PM