Dell PowerEdge R815 User Manual
Page 30
30
About Your System
E1714 Unknown
error. Review
& clear SEL.
The system BIOS
determined there has been
an error in the system, but is
unable to determine its
origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
E1715 Fatal I/O
Error. Review
& clear SEL.
The system BIOS
determined there has been a
fatal error in the system.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
E1716 Chipset IERR
Bus
##
Dev
##
Function
##
.
Review &
clear SEL.
The system BIOS reported a
chipset internal error that
resides in bus ##, device
##, function ##.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
E1717 CPU
#
internal
error. Review
& clear SEL.
The system BIOS
determined that the
specified processor has had
an internal error.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 30 Wednesday, December 18, 2013 2:48 PM