Dell PowerEdge R815 User Manual
Page 25
About Your System
25
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory voltage
regulators failed.
Reseat the memory
modules. See
E122E On-board
regulator
failed. Call
support.
One of the on-board voltage
regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1243 CPU # VCORE
Regulator
failure.
Contact
Support.
Processor voltage regulator
failed.
Reseat the processor. See
Processors" on page 168.
If the problem persists,
E1310 Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside the intended
operating range.
E1313 Fan
redundancy
lost. Check
fans.
The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.
Check LCD for additional
scrolling messages. See
E1314 Critical
system
cooling loss.
Check fans.
All fans have been removed
from the system.
Ensure that the fans are
properly installed. See
E1410 System Fatal
Error
detected.
A fatal system error
detected.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 25 Wednesday, December 18, 2013 2:48 PM