Dell PowerVault 221S (SCSI) User Manual
Page 27
Troubleshooting: Dell PowerVault 220S and 221S Systems Installation and Troubleshooting Guide
file:///C|/Users/rishi_sood/Desktop/220s/en/it/6f704c51.htm[3/7/2013 12:07:22 PM]
When a problem exists with the storage system, one or more of the following events occur:
Amber shelf fault LED is illuminated
Audible alarm sounds (when enabled)
Drive(s) not seen during the host boot
If any of these events occur, perform the following diagnostic steps:
1. Is the green AC status LED indicator on the power supply(s) illuminated? (See
No. See "
Troubleshooting a Power Supply
."
Yes. Go to
2. Are the following system components updated with the latest firmware and device drivers?
Enclosure EMM
Hard-disk drives
Host bus adapter or PERC
No. Download the latest firmware and/or drivers from support.dell.com.
Yes. Go to
3. Is the amber over-temperature LED on the front of the system illuminated? (See
No. Go to
Yes. One or more temperature sensors are in the warning range. Check environmental conditions (high ambient
temperatures, ventilation blockage, etc.) and cooling modules for failures. Replace failed cooling modules (see