8. Connect power to the power supplies.

NOTICE:

To safeguard your storage system from power problems, connect the AC power cable to a protected power

supply, such as a UPS, line conditioner, or surge protector. If your storage system includes an optional redundant

power supply, connect the two power supplies to different circuits if possible.

9. Turn on the storage system by pressing the on/off switch on the power supply. If you have a system with redundant

power supplies, make sure both on/off switches have been turned on (see

Figure 1-7

for switch locations).

10. Turn on power to the host system.

11. Check the LED indicators on the front and back of the storage system. If any amber fault indicators are illuminated, see

"

Troubleshooting

."

12. Using your array management software, enable the system's audible alarm (optional). For more information, see your

array management software.

NOTE:

The audible alarm is disabled by default.

Using Array Manager to Manage Your Storage System

Dell OpenManage™ Array Manager software provides a comprehensive storage management solution with an integrated

graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage

attached to a server while the server is online and continuing to process requests.

Array Manager obtains information about storage devices and the logical volumes contained on those devices. Array Manager

displays storage configuration information in both physical and logical views. The physical view shows the physical

connections among the storage devices. The logical view shows a logical representation of your storage as logical volumes.

From the Array Manager console, you can perform the following:

Create and manage software and hardware RAID solutions

Display your storage information

Customize the Array Manager interface to suit your individual needs

Enable the system's audible alarm

Download firmware for the enclosure

For more information on using Array Manager to configure and manage your storage system, see your Array Manager

documentation.

Changing the SCSI Bus Mode

To change your storage system's SCSI bus mode:

1. Turn off power to the storage system.