Overview
The following table is giving an overview on several kinds of PDO transmission.
Examples:

1800h

Brief explanation

Sub2

Sub5

FEh

3ms

Cyclic transmission every 3 ms

FEh

0ms

PDO transmission off

3

xxx

PDO transmission on every third sync telegram

1

xxx

PDO transmission on every sync telegram



PDO (slope angle)
PDO1 telegram structure:

COB-ID DLC

Byte 0

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

181h

8

Xx

Xx

Xx

Xx

Xx

Xx

Xx

Xx


ID

: 180h + Node-ID

Length

: 8 DataByte

Byte 0.. 3

: Slope angle in degrees axis Slope Long Y

Byte 4.. 7

: Slope angle in degrees axis Slope Lateral X



Emergency service
Internal device errors or bus problems will result in an emergency message:

COB-ID

DLC

Byte 0

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

80h+Node-
ID

8

Error Code

00h 01h

Error-

Register

1001h

Xx

Xx

Xx

Xx

Xx

Byte 0..1: Error Codes

Error Code (hex) Meaning

0000

Error Reset or No Error

1000

Generic Error

5530

EEProm error

6010

Software reset (Watchdog)

7510

Internal communication error

8130

Life Guard error or Hearbeat

Byte 2: Error-Register

Bit

Meaning

0

Generic Error

4

Communication error

7