6.1 Description of parallel encoder
In case of the parallel interface, the position value is output parallel via a maximum of 24
outputs. The following special inputs are available:
Datenwechsel
Store
Enable
t1
t2
Tristate
t4
t3
Course of signal
Runtime / typical
Time
Enable
t1 / t2
60 µs
Store
t3 / t4
200 µs
Enable: If this input is at Low level, the output drivers will be activated. If open-circuited or if
high potential is applied, the output drivers will turn to the high-resistance state.
Store:
When a Low level is applied, the data of the absolute encoder is temporarily
stored. If this input is connected to high potential or if it is open-circuited, the current
position data of the absolute encoder is switched through to the output drivers. This
line must be used to ensure safe data readout in binary code.
Caution: If the enable input is open-circuited or if high potential is applied, the output drivers
will turn to the high-resistance state (Tristate).