beautypg.com

6 appendix, Datenwechsel store enable, 1 description of parallel encoder – Baumer G1-G2-GB-GXxxx User Manual

Page 39

background image

Manual_ProGeber_V1-40_EN.doc 39/40

Baumer IVO GmbH & Co. KG

10.05.11

Villingen-Schwenningen,

Germany

6 Appendix

6.1 Description of parallel encoder

In case of the parallel interface, the position value is output parallel via a maximum of 24
outputs. The following special inputs are available:

Datenwechsel

Store

Enable

t1

t2

Tristate

t4

t3


Course of signal

Runtime / typical

Time

Enable

t1 / t2

60 µs

Store

t3 / t4

200 µs



Enable: If this input is at Low level, the output drivers will be activated. If open-circuited or if

high potential is applied, the output drivers will turn to the high-resistance state.


Store:

When a Low level is applied, the data of the absolute encoder is temporarily
stored. If this input is connected to high potential or if it is open-circuited, the current
position data of the absolute encoder is switched through to the output drivers. This
line must be used to ensure safe data readout in binary code.


Caution: If the enable input is open-circuited or if high potential is applied, the output drivers

will turn to the high-resistance state (Tristate).