4.3.4 Output logic
The function „output logic“ offers the choice between normal and inverted. In case of the
normal output logic, a logical zero is in fact displayed as zero. If, in contrast, the output logic is
inverted, a logical zero is displayed as 1.
Caution: The function "output logic", normal or inverted, refers to all 24 outputs.
Thus, the outputs for the position values are set as well.
4.3.5 Steps
The display for the steps (singleturn) shows the required outputs highlighted in blue. This
display can be used to determine the corresponding outputs for the wiring.
Caution: The steps are only shown in case of a closed code, otherwise the entire
resolution is displayed (see chapter 4.3.7 Entire resolution)
4.3.6 Revolution
The display for the revolution (multiturn) shows the required outputs highlighted in green. This
display can be used to determine the corresponding outputs for the wiring.
Caution: The steps are only shown in case of a separated code, otherwise the entire
resolution is displayed (see chapter 4.3.7 Entire resolution)
4.3.7 Entire resolution
If a closed code is set in the resolution, the entire resolution appears instead of "steps"
(singleturn) or "revolutions" (multiturn). The entire resolution is displayed in blue and
corresponds to the required outputs.