4.4.1 Output format
The output format offers the choice between „left-justified“ and „tree“. In case of the „left-
justified“ data format, the data is output starting with the revolutions. After the revolutions,
zeros are sent up to the pulse space.
In case of the „tree“ the position values is always 25 bit. If the position value is smaller, the
other digits will be padded with zeros.
Example for output format “tree” and „left-justified with zeros“:
Number of turns
Position value
Steps within on turn
4095 111111111111/1111111111111
8191
511 000111111111/1111111111000
1023
127 000001111111/1111111000000
255
7 000000000111/1111000000000
15
1 000000000001/1100000000000
3
Example for output format „left-justified“:
Number of turns
Position value
Steps within on turn
4095 111111111111/1111111111111
8191
511 111111111/1111111111000000
1023
127 1111111/111111100000000000
255
7 111/1111000000000000000000
15
1 1/110000000000000000000000
3