Baseline Systems FlowStation User Manual
Page 9

Baseline FlowStation User Manual
3. On a BaseStation 3200 irrigation controller that you want to connect to the FlowStation, turn
the dial to the Network position.
4. Press the Next button to highlight the
FlowStation Setup option.
5. Press the Enter button. The Network screen
displays.
6. In the Flow Station Control field, press the +
button to change the setting to Enabled.
7. Press the Next button to move to the first cell
of the Flow Station IP field.
8. Press the + button to change the number to
match the first group of numbers in the IP
address of the FlowStation.
Note: Press and hold the + button or the – button to rapidly increase or decrease the number
in the field.
9. Complete the IP address by pressing the Next button to move to the next cell of the Flow
Station IP field, and then pressing the + button to change the number.
10. Repeat steps 3 through 9 on each BaseStation 3200 irrigation controller that you want to
connect to the FlowStation.
Note: The connection between the controller and the FlowStation is not complete until you
assign the controller on the FlowStation. Refer to Assigning Controllers to the Shared Flow
Group on page 13.
Checking the BaseStation–FlowStation Connection Status
When the dial on the BaseStation 3200 controller is
in the RUN position, review the status of the
FlowStation connection in the FlowStn field in the
upper-right corner of the screen.
•
Wait Auth: This status displays after the
FlowStation-controller network connection
has been established and you have connected
the controller to the FlowStation. This status
continues to display until you add the
controller to the shared flow group in the
FlowStation. Refer to Assigning the
Controllers to the Shared Flow Group on page 13.
•
Connected: This status displays after the controller has been added to the shared flow group.
3 – Configuring the BaseStation 3200 Irrigation Controller for Shared Flow
Page 5