Setting up a static ip address on the flowstation – Baseline Systems FlowStation User Manual
Page 25

Baseline FlowStation User Manual
Example:
In AM/PM format
10:00A and 10:00P
In 24 hour format
10:00 and 22:00
6. When you have finished making changes, press the RUN button.
Setting Up a Static IP Address on the FlowStation
In order to have the FlowStation communicate with the BaseStation 3200 controllers in the shared
flow group, the FlowStation must be connected to a network with a supported communication
module. You need to assign a static IP address to the FlowStation to enable the BaseStation 3200
irrigation controllers in the shared flow group to connect to the FlowStation.
1. Make sure the communication module in your FlowStation is powered up and communicating
with the network.
2. On the FlowStation, press the System Setup button. The System Setup menu displays.
3. Press the button to highlight the Network Setup option, and then press the OK button to
select it. The Network Setup menu displays.
4. The IP Setup option should be highlighted. If it is not highlighted, press the or button to
highlight it, and then press the OK button. The IP Setup screen displays.
5. Press the + or – button to remove the
checkmark in the DHCP Enabled field. The
fields for the network settings display.
Note: For an explanation of the settings, refer
to Viewing the IP Information Screen on the
FlowStation on page 22.
6. Determine the static IP address that you will
assign to the FlowStation. The IP address is based on the IP addresses of the other devices on
the network, but it must have a unique last digit.
Example: The devices in your shared flow group are connected to a stand-alone network that
does not have Internet access. The communication modules in your FlowStation and
controllers have factory-assigned IP addresses in the range 192.168.111.100 -
192.168.111.105. You can set the static IP address on the FlowStation to 192.168.111.106.
7. Press the button to highlight the first digits in the IP Addr field.
Press the or button to move to the digits that you want to change.
Press the + or – button to change the value in the field.
Note: To rapidly increase or decrease the value, press and hold the + button or the – button.
8. Press the button to move to the Mask field. Use the procedure described in step 7 to move
within the digits and change the values. A typical value for the Subnet Mask is 255.255.255.0
Note: Set the Subnet Mask for all devices in your shared flow group to the same value.
9. Press the button to move to the Gateway field. Use the procedure described in step 7 to
move within the digits and change the values.
4 – Configuring the FlowStation