Operating instructions – Great Plains 3N-4025P Operator Manual User Manual
Page 94

3N-4010P, 3N-4015P, 3N-4020P and
3N-4025P
196-286M
4/23/2010
92
Operating Instructions
Drive Operational Requirements:
Hydraulic System:
Closed center, pressure compensated or load sensed systems only
Drive will not operate on open-centered hydraulic systems
Minimum Hyd Pressure:
2250 psi
Maximum Hyd Pressure:
3000 psi
Maximum Required Flow:
13 gpm
Electrical System:
Voltage:
12 volt DC
Amperage:
4 amperes
Tractor Hookup
Hydraulics:
1.
Connect pressure hose (P) to retraction outlet.
2.
Connect motor return hose (T) to motor return port (if available) or extension outlet.
3.
Set flow rate at approximately 13 gpm.
4.
If tractor is equipped with electro-hydraulic valves, set timer to “constant” flow.
Electrical:
1.
Power can be connected in three different manners:
a.
Power port adapter (PN 19676)