Great Plains 3N-4025P Operator Manual User Manual
Page 104

3N-4010P, 3N-4015P, 3N-4020P and
3N-4025P
196-286M
4/23/2010
102
Refer to Figure 27
When the tractor passes the second flag, press
Engage key again.
Refer to Figure 28
The display will show the error or difference be-
tween the traveled distance and the distance
calculated by the controller.
Refer to Figure 29
If this is the first time the unit has been calibrated,
this error can be large. Accept the new speed cal-
ibration and rerun the course. Recalibrate until the
error is within 5%. The cab console will give you
the option each time you calibrate of accepting the
new settings or keeping the previous settings.
22792
22793
22794
Figure 27
Figure 28
Figure 29