Great Plains 3PYP Predelivery Manual User Manual
Page 60

56 3PYP
401-312Q
07/19/2011
Track Tractor Preferred Method of Tractor Steering
Sensor Calibration
19. Turn the Ignition Switch to the ON position. DO NOT
START the ENGINE.
20. Put the Steer Toggle switch to the ON position. The
power light on the steering switch box and the LED’s
on the electronic steering module should all be illu-
minated.
21. Put the steering in the tractor sensor calibration
mode by setting Calibration switch
to the
TRACTOR position.
Note: Do not move the Calibration toggle switch from the
TRACTOR position until step 28 or the new tractor
calibration is ignored.
22. Turn the steering wheel all the way to the right and
hold in this position to simulate a hard right hand
turn.
23. Press and hold the LEARN button
on the switch
box until the LEARN indicator
flashes.
24. Release the steering wheel. It should return to the
center position.
25. Press and hold the LEARN button
on the switch
box until the LEARN indicator
flashes.
26. Turn the steering wheel all the way to the left and
hold in this position to simulate a hard left hand turn.
27. Press and hold the LEARN button
on the switch
box unti lthe LEARN indicator
flashes.
28. Complete the tractor sensor calibration mode by
setting Calibration switch
to OFF. Only at this
point are the new calibration values accepted by the
system.
4
5
6
5
6
5
6
4