17. Secure the lid on the inductor tank.
18. Turn off the pump.
19. Set the product valve
to OFF.
Agitation
Refer to Figure 39
The agitator system bleeds of some of the material flow
and recirculates it through quad jet orifices at the bottom
of the tank. It helps maintain constant concentration with
materials that might otherwise tend to precipitate, sedi-
ment or stratify.
The agitation valve
adjusts the pressure to the agita-
tion nozzles in the tank when set to positions in between
OFF and AGITATION.
Refer to the agitation gauge
, and adjust the pressure
to a desired rate. Different chemicals require different
agitation pressures to keep the chemical in suspension.
(see chemical label).
Foam Marker Tank Fill
Consult the separate manual provided with the marker
system for information on selecting, mixing, loading and
applying marker foam.
Figure 38
Inductor Valves On
14993
5
4
4
Figure 39
Agitation Valve
27275
1
18
1