beautypg.com

Rate calibration – Great Plains TSF1290 Operator Manual User Manual

Page 38

background image

34

TSF1080, TSF1090, TSF1280 & TSF1290

Great Plains Manufacturing, Inc.

500-641M

05/10/2012

Rate Calibration

Current TSF1080, TSF1090, TSF1280 & TSF1290
sprayers include a Raven SCS 450 controller as stan-
dard equipment, and the SCS 450 system includes a
flow rate sensor in the boom plumbing. This supports
direct real-time readout of the current application rate.

For a newer sprayer, perform the rate calibration proce-
dures from the Raven SCS 450 manual.

For an older sprayer without an SCS 450, perform the fol-
lowing steps.

1.

Determine the nozzle rate (gpm or liters/min) at
which your chemical should be sprayed. In determin-
ing the rate, and which spray nozzles to use with
your sprayer, you need to know:

2.

Using this information, calculate the nozzle rate, per
nozzle, per a formula below:

Using 0.34 gpm and pressure 30 psi, you would
select a nozzle from your nozzle chart that comes
closest to providing the desired output.

3.

Turn on your sprayer and adjust the pressure.

4.

While operating the sprayer at desired pressure,
catch the discharge in the calibration container for
one minute. For U.S. customary units, divide the
number of ounces caught by 128 to determine gal-
lons per minute (GpM) per nozzle. 128 fluid ounces
equals one gallon.

Parameter

Units

Your value

Data Source

Nozzle SpacingIn or SpacingCm

inch or cm

from sprayer configuration (page 17)

Target GpA or LpHa

g/ac or liters/Ha

From material container or supplier

Intended Mph ok Kph

mph or kph

From course trial above

Nominal application psi or kg/cm

2

psi or kg/cm

2

from GP slide chart

Example:
Nozzle Spacing: 20 in
Speed: 5.05 mph
Pressure: 30 psi

Nozzle Rate = 0.34 Gallons Per Minute

20

5.05

20

Ч

Ч

5940

-------------------------------

0.34

=

NozzleGpM

GpA

Mph

×

SpacingIn

×

5940

----------------------------------------------------------

=

NozzleLpM

LpHa

Kph

×

SpacingCm

×

60000

--------------------------------------------------------------

=

Example:
Sample: 44 U.S. Fluid Ounces in 1 minute

Nozzle Rate = 0.34 Gallons Per Minute

44

128

-------

0.34

=

NozzleGpM

SampleOuncesPerMinute

128

--------------------------------------------------------------

=

This manual is related to the following products: