Hydraulic valve control, Foam marker control (option) – Great Plains TSF1290 Operator Manual User Manual
Page 34
30
TSF1080, TSF1090, TSF1280 & TSF1290
Great Plains Manufacturing, Inc.
500-641M
05/10/2012
The following data is needed for Raven setup:
Hydraulic Valve Control
Refer to Figure 24
Install the Fasse valve switch box in a convenient loca-
tion in the tractor cab.
The Fasse controller requires a connection to the tractor
battery. Use the 6 ft, two-wire red and black cable to con-
nect the hydraulic controls. Connect red wire from each
cable to positive terminal and black wire from each cable
to negative terminal.
If no foam marker is installed, one 4-pin connector
is
not used.
Foam Marker Control (Option)
This option includes a separate installation and operation
manual.
If ordered with the sprayer, the foam marker is factory-
installed and cabled to the Fasse harness.
Model
Description
BOOM CAL
SPEED CAL
METER CAL
VALVE CAL
TSF-1080-3330
1000 Gallon 80
foot 30in spacing
990in (2515 cm)
598
*
*
Suggested initial value. Refine using calibration procedure in Raven SCS 450 manual.
Cable Tag
†
† This value is printed on a durable tag attached to the meter cable.
Body Label
‡
‡ This value, typically “2123”, is printed on the label on the valve body.
TSF-1080-4820
1000 Gallon 80
foot 20in spacing
960 in (2438 cm)
598
Cable Tag
TSF-1090-3730
1000 Gallon 90
foot 30in spacing
1110 in (2819 cm)
598
Cable Tag
TSF-1090-5420
1000 Gallon 90
foot 20in spacing
1080 in (2743 cm)
598
Cable Tag
TSF-1280-3330
1250 Gallon 80
foot 30in spacing
990in (2515 cm)
598
Cable Tag
TSF-1280-4820
1250 Gallon 80
foot 20in spacing
960 in (2438 cm)
598
Cable Tag
TSF-1290-3730
1250 Gallon 90
foot 30in spacing
1110 in (2819 cm)
598
Cable Tag
TSF-1290-5420
1250 Gallon 90
foot 20in spacing
1080 in (2743 cm)
598
Cable Tag
Figure 24
Fasse Valve Switch Box
27272
1
1