beautypg.com

Great Plains TSF1290 Operator Manual User Manual

Page 43

background image

Great Plains Manufacturing, Inc.

Operations

39

05/10/2012

500-641M

Valves operate by moving their handles to point at the
function on the decal, or toward the pipe desired on an
otherwise unmarked selector valve. Shut-off valves are
open when the handle is parallel to the piping, and
closed when the handle is perpendicular.

Fluid is drawn from the main tank

via the sump

and passes through the

pump. The illustration shows

an Ace hydraulic pump, but your pump may be PTO or a
non-standard installation.

From the pump, fluid passes through the solution Whirlfil-
ter®

, which filters out or grinds up all undissolved

chemical and solid particles. The fluid then passes
through both the flow meter

and the bypass control

butterfly valve

.

The bypass control butterfly valve

controls how much

fluid goes to the boom. This is regulated by the Raven
SCS 450 controller. The fluid passes through the flow
meter

and proceeds to the 5-Way Boom Manifold

valves. If a boom valve is on, the fluid passes to its
respective boom section and is sprayed out the individual
nozzles. See page 83 for a layout of the boom plumbing.

The agitation is set by adjusting the agitation pressure
valve

while the pump is at operating speed. Refer to

Application Guide to adjust the agitation.

The optional inductor

provides convenient pump-

driven loading of concentrates into the main tank.

There are tank shut off valves (

-

) at each inlet and

outlet. Use these to prevent spills and isolate any leaks.

To operate a correctly connected hydraulic pump, push
the hydraulic lever in the “down” position. When you want
to stop the pump, put the hydraulic lever in the “float”
position.

Do not move the hydraulic lever to the neutral position while
the hydraulic pump is running. To do so may cause damage to
the hydraulic pump.

Pump

Solution Whirlfilter®

Flow Meter

Bypass Control Butterfly Valve

5-Way Boom Manifold Valves

Agitation Gauge

Inductor

Main Inlet Quick Connect

Main Inlet Filter

Flush Tank Inlet Quick Connect

Manual Throttle Valve

Agitator Inlet Shutoff Valves (Normally Open)

Main Inlet Shutoff (Normally Closed)

Flush Tank Inlet Shutoff (Normally Closed)

Main Tank Sump Shutoff (Normally Open)

Whirlfilter Cleanout Shutoff Valve (Normally Closed)

Inductor Outlet/Tank Inlet Shutoff Valve (N.Open)

13

14

15

16

17

18

19

20

21

22

23

30

31

32

33

34

35

10

12

13

14

15

16

16

15

17

1

15

30

35

This manual is related to the following products: