Great Plains TSF1290 Operator Manual User Manual
Page 43
Great Plains Manufacturing, Inc.
Operations
39
05/10/2012
500-641M
Valves operate by moving their handles to point at the
function on the decal, or toward the pipe desired on an
otherwise unmarked selector valve. Shut-off valves are
open when the handle is parallel to the piping, and
closed when the handle is perpendicular.
Fluid is drawn from the main tank
and passes through the
pump. The illustration shows
an Ace hydraulic pump, but your pump may be PTO or a
non-standard installation.
From the pump, fluid passes through the solution Whirlfil-
ter®
, which filters out or grinds up all undissolved
chemical and solid particles. The fluid then passes
through both the flow meter
and the bypass control
butterfly valve
.
The bypass control butterfly valve
controls how much
fluid goes to the boom. This is regulated by the Raven
SCS 450 controller. The fluid passes through the flow
meter
and proceeds to the 5-Way Boom Manifold
valves. If a boom valve is on, the fluid passes to its
respective boom section and is sprayed out the individual
nozzles. See page 83 for a layout of the boom plumbing.
The agitation is set by adjusting the agitation pressure
valve
while the pump is at operating speed. Refer to
Application Guide to adjust the agitation.
The optional inductor
provides convenient pump-
driven loading of concentrates into the main tank.
There are tank shut off valves (
) at each inlet and
outlet. Use these to prevent spills and isolate any leaks.
To operate a correctly connected hydraulic pump, push
the hydraulic lever in the “down” position. When you want
to stop the pump, put the hydraulic lever in the “float”
position.
Do not move the hydraulic lever to the neutral position while
the hydraulic pump is running. To do so may cause damage to
the hydraulic pump.
Pump
Solution Whirlfilter®
Flow Meter
Bypass Control Butterfly Valve
5-Way Boom Manifold Valves
Agitation Gauge
Inductor
Main Inlet Quick Connect
Main Inlet Filter
Flush Tank Inlet Quick Connect
Manual Throttle Valve
Agitator Inlet Shutoff Valves (Normally Open)
Main Inlet Shutoff (Normally Closed)
Flush Tank Inlet Shutoff (Normally Closed)
Main Tank Sump Shutoff (Normally Open)
Whirlfilter Cleanout Shutoff Valve (Normally Closed)
Inductor Outlet/Tank Inlet Shutoff Valve (N.Open)
1