Identify rows to shut off, Close seed shutter, Install blank disk – Great Plains 3PYPA Operator Manual User Manual
Page 84: Close y-tubes
80
3PYPA
Great Plains Manufacturing, Inc.
401-647M
03/20/2012
1. Identify Rows to Shut Off
On twin-row planters, openers are installed with short
and long opener mounts. If locking up unused rows of a
twin-row planter, shut off the rear (long mount) rows.
On single-row planters with mid-length mounts, any rows
may be locked up.
2. Close Seed Shutter
Refer to Figure 107 on page 79
Lift the handle
away from the plate. Move it to the top
position, and release the handle into the notch.
Closing the shutter
prevents meter pressurization air
from leaking into the bulk seed air system, resulting in
lower pressures in adjacent rows, with risk of skips.
The shutter also stops seed flow from a row as soon as
the meter is empty. Bulk seed flow to the row falls to nil
as soon as the seed backs up to the air release vent at
the top of the meter. If the row is served by a Y-tube, the
Y-tube also needs to be shut off for the row (step 4).
3. Install Blank Disk
Refer to Figure 108
Clean out meter. See “Meter Clean-Out” on page 102.
Remove seed disk and install blank disk. See “Air-Pro®
Meter Disk Installation” on page 78.
Blank disks (part number 817-841C) are essential in row
shut-off, both to maintain consistent meter back-pressure
to meter pressurization and to prevent wear on a seed
disk.
Blank disks are engineered to simulate a seed disk with
seed in all pockets. Blanks are particularly important on
the rows with sensor lines to the pressure chamber.
4. Close Y-Tubes
Refer to Figure 109
If any shut-off rows are served by a Y-tube, close the
valve for the branch to that row. Rotate the valve cap until
the indicator/handle is perpendicular to the tubes.
Closing the Y-tube prevents seed from entering an
unused hose, reducing waste and simplifying clean-out.
Null4:
Null4:
Irregular Seeding Risk:
Always use a blank disk in a shut-off row. Operating with no
disk, or with a seed disk but no seed, destabilizes the regulated
airflow, particularly at rows with pressure sensor lines.
Figure 108
Shutter Closed, Blank Disk Installed
29610
2
1
Null4:
Figure 109
Y-Tube Open and Closed
29758