Unit-mounted row options, Lock-up pins, Row cleaners – Great Plains 3PYPA Operator Manual User Manual
Page 138

134
3PYPA
Great Plains Manufacturing, Inc.
401-647M
03/20/2012
Unit-Mounted Row Options
Lock-Up Pins
If rows are shut off, you can reduce unnecessary wear
on the unused row units by locking them up. Twin-row
planters include, as standard, one lock-pin per rear row.
For replacement pins, or for other planter models, order
one per row unit locked-up.
See “Row Unit Shut-Off” on page 79.
Row Cleaners
Optional Martin row cleaners are unit-mounted, either:
• “stand-alone”, using a unit-mount assembly (
), or;
• added to a UMC coulter disk mounting bracket (
,
with or without a disk).
Twin-Row planters and narrow row spacings support
only single-wheel unit-mounted row cleaners, in alternat-
ing left/right cleaner hub orientations.
Row cleaners are not recommended for row spacings of
10in (25.4cm) or less.
Coulter-mounted (requires coulter):
Stand-alone (includes mount):
For operations, see:
“Unit-Mount Cleaner Adjustments” on page 70.
Description
Part Number
PIN HITCH 1 X 6 W/HAIRPIN
805-033C
Description
Order Number
Single-wheel, 16 pair of left/right
207-107A
Single-wheel, 12 pair of left/right
207-108A
Double-wheel, 16 rows
207-113A
Double-wheel, 16 rows
207-125A
Double-arm, 12 rows
207-126A
Description
Order Number
Single-wheel, 16 pair of left/right
207-111A
Single-wheel, 12 pair of left/right
207-112A
Double-wheel, 16 rows
207-117A
Double-arm, 12 rows
207-129A
Double-wheel, 12 rows
207-130A
Null4:
27226
Null4:
27345
2
1
207-xxK and -xxS kits do not include a manual.
Individual Row Cleaners
Part Number
UMRC Dual Wheel
207-213K
UMRC LH Single Wheel
207-215K
UMRC RH Single Wheel
207-216K
UMC-RC Dual Wheel
207-098S
UMC-RC LH Single Wheel
207-092S
UMC-RC RH Single Wheel
207-093S
RC Install/Use/Parts Manual
204-085M-A
1
2