beautypg.com

Programming instructions (continued) – SARGENT Keypad Exit Devices User Manual

Page 21

background image

Copyright © 2006, 2008, Sargent Manufacturing Company

, an A

SSA ABL

O

Y Group company

. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

800-810-WIRE (9473) • www.sargentlock.com • A7137B

Chain Programming of the KP8800 and KP8900 Series Exit Device (including 12-)

When programming multiple User Numbers and Codes into the Keypad Exit Device, it is not necessary to leave and re-
enter the programming Mode (50) for each entry. Multiple entries may be chained together and the three different types of
user codes (Standard, Passage and One time) may be mixed.

The format to be used is as follows where:
“T” is the Type of user code with “1” Standard, “2” Passage and “3” One Time.
“UN_” is User Number (04-99).
“UC_” is User Code (2 to 6 digits) which correlates with user Number.

99# Master or Supervisor Code* 50# Type# User Number a# User Code a* User Code a* T# UNb# UCb* UCb*
T# UNc# UCc* UCc* ……T# UN_# UC_* UC_**

An example with four user codes is shown below:

Using Master Code 4732 and above information, the keypad exit device would be programmed as follows:
99# 4732* 50# 1# 05# 875* 875* 3# 12# 2226* 2226* 2# 08# 5444* 5444* 1# 50# 3367* 3367**

If all user codes are the same type, it is not necessary to enter the type number with each entry. The type number only has
to be entered with the first user code. The format now simplifies to:

99# Master or Supervisor Code* 50# Type# User Number a# User Code a* User Code a* UNb# UCb* UCb*
UNc# UCc* UCc* ……UN_# UC_* UC_**

An example with three user codes is shown below:

Using Master Code 45988 and above information, the keypad exit device would be programmed as follows:
99# 45988* 50# 1# 07# 77* 77* 15# 67832* 67832* 91# 7568* 7568**

To chain the User Number delete procedure:
99# Master Code* User Number a#** UNb#** UNc#** ……UN_#****

Using the information from the above example:
99# 45988* 07#** 15#** 91#****

Type

User Number

User Code

1

05

875

3

12

2226

2

08

5444

1

50

3367

Type

User Number

User Code

1

07

77

1

15

67832

1

91

7568

19

5

Programming Instructions