To Enter the Supervisory Code:
99# Master Code
*
Yellow LED begins to blink slowly
50# 1# 03# Supervisory Code
*
Yellow LED blinks quickly
Supervisory Code
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Enter a User Code:
99# Supervisory or Master Code
*
Yellow LED begins to blink slowly
50# 1# User Number (04-97)# User Code
*
Yellow LED blinks quickly
User Code
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Enter a Passage (Maintained Mode) Code:
When Passage Mode is used, the same User Code must be used to Re-lock the lock.
99# Supervisory or Master Code
*
Yellow LED begins to blink slowly
50# 2# User Number (04-97)# User Code
*
Yellow LED blinks quickly
User Code
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Enter a One-Time User Code:
99# Supervisory or Master Code
*
Yellow LED begins to blink slowly
50# 3# User Number# User Code
*
Yellow LED blinks quickly
User Code
*
Yellow LED blinks slowly
*
Yellow LED goes out
To Deactivate “Beep” with the Depression of Each Key:
99# Supervisory or Master Code
*
Yellow LED begins to blink slowly
30# 0# 0#
Yellow LED continues to blink slowly
*
Yellow LED blinks quickly
*
No beep on depression and yellow LED blinks slowly
*
No beep on depression and yellow LED goes out
To Reactivate “Beep” with the Depression of Each Key:
99# Supervisory or Master Code
*
Yellow LED begins to blink slowly
30# 0# 1#
Yellow LED continues to blink slowly
*
Yellow LED blinks quickly
*
Beep on depression and yellow LED blinks slowly
*
Beep on depression and yellow LED goes out
To Clear the Entire Memory:
99# Master Code
*
Yellow LED begins to blink slowly
46# 00000# 00000#
Yellow LED continues to blink slowly
*
Yellow LED blinks quickly
*
No beep on depression and yellow LED goes out
PAUSE
Yellow LED begins to blink slowly again
*
Yellow LED goes out
NOTE: This deletes ALL codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234, Door Number to 0001 and Unlock time
to 5 sec. If the Master Code is not known, Factory Assistance will be required to clear the memory. 1-800-810-WIRE.
To Program Door Numbers into Keypad:
99# Master Code
*
Yellow LED begins to blink slowly
43# 0# Door Number# (Must be four digits)
Yellow LED blinks slowly
*
Yellow LED begins to blink quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out