The Keypad Exit Device Lock can support 100 users. Each user is
assigned a User Number in addition to the code used for entry.
Example:
USER
USER
USER CODE
TYPE
NUMBER
(2-6 DIGITS)
Master
01
1 2 3 4
Emergency
02
2 2 2 2 2
Supervisor
03
3 0 3 0 3 0
Standard
04-97
2 6 5
Special Factory
98
10 Sec. Time Preset
99
1 3 6 8
This Keypad Exit Device Lock has 99 User Codes available for programming purposes.
• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used
for programming. Users are deleted through the Master Programming Code only.
• The Emergency Code is always User “02”. The Emergency Code will override the deadbolt in the mortise lock and has an
unlock time of 10 seconds.
• The Supervisory Code is always User “03”. The Supervisory Code allows temporary lockout of selected users, changes
duration of unlock time, requests infrared interrogation output, and may add additional User Codes.
• The first User Code will be User “04” or higher. User numbers do not have to be used or entered sequentially.
• User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person extra time
which would not be required by other users.
To Begin Programming:
The Keypad Exit Device Lock is preset at the factory with Master Code “1234”. Entering 1234
*
will unlock the lock allowing
the lever handle to retract the latchbolt.
Initial Set-Up Procedures:
• The following are typical procedures to follow when setting up your KP Exit Series Keypad.
• If a mistake is made during any of procedures, depress the “
*
” several times until the yellow LED goes out.
• If no keystroke is made in a 30sec time frame the programming up to that point will default and you will have to start over.
• If after the last “
*
” is depressed, the yellow LED does not go out, depress “
*
” once more.
Change the Master Code:
99# 1234
*
Yellow LED begins to blink slowly
50# 1# 01# New Master Code
*
Yellow LED blinks quickly
New Master Code
*
Yellow LED blinks slowly
*
Yellow LED goes out
This example uses the Factory Default Master Code
To Enter the Emergency Code:
99# Master Code
*
Yellow LED begins to blink slowly
50# 1# 02# Emergency Code
*
Yellow LED blinks quickly
Emergency Code
*
Yellow LED blinks slowly
*
Yellow LED goes out