beautypg.com

Cnc functions, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 380V User Manual

Page 88

background image

AUTO-CUT 200 XT

A-2

APPENDIX

Manual 0-5253

CNC FUNCTIONS.

CNC I/O circuits provide at least 1000V galvanic isolation from the plasma power supply.

While the CNC circuits are isolated from the power supply, many of the signal returns on J15 and TB1 & 2 are com-

mon to each other. J15 pins 1, 4, 5 & 10 and TB1-1, 5, 7, 9, and TB2-1 & 3 are all common. J15 pin 12 and TB2-10 are

also connected to the others when SW6 (OK to Move select) is set for voltage.

Rear Panel CNC Connector J15:
14 Circuit (Amp CPC) Remote Standard:
Chassis gnd (for SC-11 cable shield)

1

1

Start/Stop

3 (+); 4 (-)

1

Ok to Move (contacts or voltage

2

)

12(-); 14 (+)

1

Divided Arc volts (selectable

ratio 50:1; 40:1; 30:1; 16.6:1, 25:1)

5 (-); 6 (+)

PreFlow ON

7 (+); 9 (-)

Corner Current Reduction

10 (+); 11 (-)

Isolated Circuit Comm (for SC-11)

8

Chassis Gnd

13

1

These are also duplicated on TB1, TB2 & TB3 use one or the other not both. Additional functions are only available

on TB1, TB2 & TB3.

2

SW6 on CCM I/O PCB selects OK to Move for isolated contact closure or DC Volts (15-18V) at <100ma. When

set for contacts, OK to Move circuit is rated for 120 VAC / 28 VDC @ 1A.