Auto-cut 200 xt – Tweco 200 XT Auto-Cut 380V User Manual
Page 55
AUTO-CUT 200 XT
Manual 0-5253
OPERATION
4-7
3. Set Gas Pressures
a. Place RUN/SET switch in SET mode.
b. Adjust plasma and shield pressure regulators to correct pressure or correct flow if using H
2
O Mist option.
(refer to manual Section 2 for required pressure/flow.)
c. Return RUN/SET switch to RUN mode. Attempting to START while in the SET mode will cause fault
L303, normally indicating low gas pressure but in Auto-Cut XT units also indicates trying to START while
in SET.
4. Set cutting current.
a. Adjust the Current Control knob to the required output current on the 4 digit display.
5. Prepare to cut.
a. Protect your eyes and ears.
b. Position the Torch to the proper transfer distance above the work piece.
6. Apply START.
• Gas indicator lights; Gas pre-flow starts.
• During gas pre-flow power supply is enabled. DC lamp turns ON.
7. Pilot Arc
• At the end of pre-flow, ignition occurs (arcstarter fires) and the Pilot Arc is established.
8. Transfer
• Almost immediately, if the torch is positioned correctly, the pilot arc transfers to the work and becomes
a cutting (transferred) arc.
• Current quickly ramps up to the level set by the Current Control and the arc pierces through the metal.
• OK to Move signal becomes active and the torch is moved to perform the cut.
9. End of Cut
• START signal is removed; current ramps down and the arc goes out.
• Gases continue to flow for the selected Post-flow time then stops.
• Pump will run for 4 minutes then shut off. Fan will remain on as long as power is on.
10. To make another cut repeat steps 5-9. A second cut can be started anytime after completing the first cut.