beautypg.com

Auto-cut 200 xt – Tweco 200 XT Auto-Cut 380V User Manual

Page 139

background image

AUTO-CUT 200 XT

Manual 0-5253

APPENDIX

A-53

PWR Present

• When power is first applied to the inverter (contactor closed) CCM checks for presence of the +12V bias

on the Inverter Control and Fault board. If not present will set codes in the range of 265-270.

IS_ID (A, B, or C)

VAC_SEL (A or B)

201

Missing AC Phase

The System Bias Supply board contains circuits to detect if one of the 3 AC input phases is missing. Along with

that it can also detect if the AC voltage is too low or too high. Three phase voltage is supplied from the input

terminals through the ON/OFF Switch / circuit breaker CB1 to the System Bias board. The System Bias can

operate on any 2 of the 3 phases to supply control power and fault detection.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J62

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J27

GND

+V

1

2

4

3

HCPL-817

U?

Missing Phase a

Missing Phase b

GND

To CPU PCB

J29-16

Missing Phase

I/O PCB

SYSTEM BIAS PCB

CB1

ON / OFF

F2

F1

J60-9,18

J60-5,14
J60-1,10

3 phase AC

Art # 12310

Normally when the phase is not missing the transistor is on which turns on the opto-isolator making the signal

“Missing Phase” low.

Causes for 201, missing phase code. Codes are displayed two different ways, with an “L” meaning “Latched”

or “Last”, before the number meaning it was a problem but isn’t right now or with an “E” meaning the problem

exists now.

L201 :

Most likely cause is an intermittent problem with the incoming power or possibly a loose connection on the

power cord at the back or the Ultra-Cut or Auto-Cut plasma supply.

E201:

• Phase missing from the wall fuse box, blown fuse.
• F1 or F2, 8A 500V slow blow fuses blown.
• CB1 one phase open.
• System Bias board defective.
• I/O board defective.

Troubleshooting:

1. System Bias board has a red LED, D3, that lights if it detects a missing phase. If D3 is on, check J60 for all 3

phases.

a. If all 3 phases are not present at J60 check for incoming power, then the F1 & F2 fuses. Finally the CB1.

b. If all 3 phases present and about equal voltage then change the System Bias board.

2. If D3, Missing Phase LED, is not on check for voltage at J27-3 & 4 on the CCM. Normal voltage, with no

missing phase, at J27 (or J62 on the System Bias board) pin 3 and pin 4, relative to I/O PCB ground. (TP1)

should be between 10-14VDC with pin 3 being a couple volts higher than pin 4. If this is normal, problem

may be in the CCM.

3. If the voltage at J27-3 & 4 is higher than 10-14VDC and up to 20-24VDC, make the same measurement at

J62 pin 4. If still high there and you have confirmed all 3 phases are present at J60 then the System Bias is

defective.

4. If the voltage at J62-4 is not high the wires between J27 and J62 may be broken.