Auto-cut 200 xt – Tweco 200 XT Auto-Cut 380V User Manual
Page 61

AUTO-CUT 200 XT
Manual 0-5253
OPERATION
4-13
Code
Message
Remedy / Comments
249
Inverter 2A Circuit
Fault
Inverter Module 2 Section A detected a circuit fault; Damaged Inverter Module 2
250
Not used
Reserved for other models with additional inverter sections.
251
Not used
Reserved for other models with additional inverter sections.
252
Not used
Reserved for other models with additional inverter sections.
253
Inverter 1A Over
Temp
Inverter Module 1 Section A detected an over temperature fault; Check for restricted air flow,
clogged radiator; Defective fan; If problem persists replace inverter module.
254
Inverter 1B Over
Temp
Inverter Module 1 Section B detected an over temperature fault; Check for restricted air flow,
clogged radiator; Defective fan; If problem persists replace inverter module.
255
Inverter 2A Over
Temp
Inverter Module 2 Section A detected an over temperature fault; Check for restricted air flow,
clogged radiator; Defective fan; If problem persists replace inverter module.
256
Not used
Reserved for other models with additional inverter sections.
257
Not used
Reserved for other models with additional inverter sections.
258
Not used
Reserved for other models with additional inverter sections.
259
Inverter 1A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
260
Inverter 1B Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
261
Inverter 2A Over
Temp Ambient
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.
262
Not used
Reserved for other models with additional inverter sections.
263
Not used
Reserved for other models with additional inverter sections.
264
Not used
Reserved for other models with additional inverter sections.
265
Inverter 1A No Input
Power
Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
266
Inverter 1B No Input
Power
Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
267
Inverter 2A No Input
Power
Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
268
Not used
Reserved for other models with additional inverter sections.
269
Not used
Reserved for other models with additional inverter sections.
270
Not used
Reserved for other models with additional inverter sections.
271
Inverter ID reading
fault
CCM found ID values inconsistant during reading. CCM to an Inverter section ribbon dam-
aged or disconnected; Inproper ribbon cable routing.