Section 3: installation, 01 installation requirements, Section 3: installation -1 – Tweco 200 XT Auto-Cut 380V User Manual
Page 25: Installation requirements -1, Auto-cut 200 xt

AUTO-CUT 200 XT
Manual 0-5253
INSTALLATION
3-1
SECTION 3: INSTALLATION
3.01 Installation Requirements
Electric Supply
The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity must be checked by qualified personnel.
Auto-Cut 200 XT™Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
380
50/60
41
63
100
#6
16
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011
edition published by the National Fire Prevention Association. Listings are from table
400.5(A)(2) for flexible cord of certain types rated for 75 deg C in ambient tempera-
tures up to 30 deg C. Using wires of lower temperature rating or different insulation
type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to
your region for final determination of correct wire type and size.
CAUTION
Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.
Gas Supply
The customer must supply all gas and pressure regulators. Gases must be of high quality. Pressure regula-
tors must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause
one or more of the following problems:
• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.
Cooling System Requirements
Coolant must be added to the system on installation. The amount required varies with torch leads length.
Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).
Coolant Capabilities
Cat. Number and Mixture
Mixture
Protects To
7-3580 ‘Extra-Cool
TM
’
25 / 75
10° F / -12° C
7-3581 ‘Ultra-Cool
TM
’
50 / 50
27° F / -33° C
7-3582 ‘Extreme Cool
TM
’
Concentrate* -65° F / -51° C
* For mixing with D-I Cool
TM
7-3583