beautypg.com

Appendix, Appendix 1: sequence of operation (block diagram), Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual

Page 71

background image

CUTMASTER 35mm, 40mm

Manual 0-5118 A-1 APPENDIX

APPENDIX 1: SEQUENCE OF OPERATION

(BLOCK DIAGRAM)

ACTION:

ON / OFF switch to ON

RESULT:

AC indicator ON.

GAS indicator ON

when input

pressure is adequate

for power supply operation.

Power circuit ready.

ACTION:

Protect eyes and activate

Torch switch (START)

RESULT:

Fans turn on. Gas flows briefly,

then stops.Gas restarts.

DC indicator ON

Pilot arc established.

ACTION:

Unplug input

power cord or

open external

disconnect.

RESULT:

No power to system.

ACTION:

Connect work cable to workpiece.

Set output amperage.

RESULT:

System is ready

for operation.

ACTION:

RUN /

Rapid Auto Restart /
SET / LATCH switch

to SET

RESULT:

Gas flows to set

pressure.

ACTION:

RUN / Rapid Auto Restart /

SET / LATCH

switch to RUN

(for most applications)

or to

Rapid Auto Restart

(for gouging, trimming,

or expanded metal

applications)

or to

LATCH

is used for specific applications

(torch switch can be released

after main arc transfer).

RESULT: Gas flow stops.

ACTION:

Release Torch switch.

RESULT:

Main arc stops.

Gas flow stops after post - flow.

(Fans will continue to run for

10 minutes after the Torch switch

[START] is removed)

ACTION:

ON / OFF switch

to OFF

RESULT:

All indicators off.

Power supply fans shut off.

ACTION:

Close external

disconnect switch.

RESULT:

Power to system.

ACTION:

Torch moved within

transfer distance of workpiece.

RESULT:

Main arc transfers.

Pilot arc off.

PILOT ARC

ACTION:

Torch moved away from work (while

still activated).

RESULT:

Main arc stops.

Pilot arc automatically

restarts.

Art #A-07979_AB