05 input wiring specifications, Input wiring specifications -3, Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual
Page 17
CUTMASTER 35mm, 40mm
Manual 0-5118 2-3 INTRODUCTION
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
30.5"
774.7 m
63 lb / 28.6 kg
10.75"
273 mm
16.375"
416 mm
Art # A-08358
6"
150 mm
24"
610 mm
6"
150 mm
6"
150 mm
Art # A-07925_AB
2.05 Input Wiring Specifications
CutMaster 35mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse (amps)
Flexible Cord
(mm
2
)
Flexible Cord
(AWG)
3 Phase
380
50
18.4
28
25
32
6
10
400
50
18.7
27
24
32
6
10
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
CutMaster 40mm Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I eff
Fuse (amps)
Flexible Cord
(mm
2
)
Flexible Cord
(AWG)
3 Phase
380
50
23
35
32
40
10
8
400
50
23.6
34
31
40
10
8
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installa-
tions refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.