04 power supply specifications, Power supply specifications -2, Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual
Page 16
CUTMASTER 35mm, 40mm
INTRODUCTION 2-2 Manual 0-5118
2.04 Power Supply Specifications
CutMaster 35 Power Supply Specifications
380 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
400 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
Input Power Cable
Power Supply includes input cable.
Output Current
30 - 100 Amps, Continuously Adjustable
Power Supply Gas Filtering Ability
Particulates to 5 Microns
CutMaster 35 Power Supply Duty Cycle *
Ambient Temperature
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
All Units
Duty Cycle
60%
80%
100%
Current
100
80
70
IEC
IEC
IEC
DC Voltage
120
120
116
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low or the output voltage
(DC) is higher than shown in this chart.
CutMaster 40 Power Supply Specifications
380 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
400 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
Input Power Cable
Power Supply includes input cable.
Output Current
30 - 120 Amps, Continuously Adjustable
Power Supply Gas Filtering Ability
Particulates to 5 Microns
CutMaster 35 Power Supply Duty Cycle *
Ambient Temperature
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
All Units
Duty Cycle
N/A
40%
100%
Current
120
100
IEC
IEC
IEC
DC Voltage
128
124
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low or the output voltage
(DC) is higher than shown in this chart.
**Using a 208/230 VAC input will reduce this duty cycle to 50%
NOTE
IEC Rating is determined as specified by the International Electro-Technical Commission. These specifica-
tions include calculating an output voltage based upon power supply rated current. To facilitate comparison