beautypg.com

2t.04 options and accessories, 2t.05 introduction to plasma, Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual

Page 20

background image

CUTMASTER 35mm, 40mm

INTRODUCTION 2T-2 Manual 0-5118

F. Torch Ratings

Manual Torch Ratings

CUTMASTER 35mm

Ambient Temperature

104° F

40° C

Duty Cycle

100% @ 100 Amps @ 400 scfh

Maximum Current

100 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

Manual Torch Ratings

CUTMASTER 40mm

Ambient Temperature

104° F

40° C

Duty Cycle

100% @ 120 Amps @ 400 scfh

Maximum Current

120 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

G. Gas Requirements

Manual and Mechanized Torch Gas Specifications

Gas (Plasma and Secondary)

Compressed Air

Operating Pressure

Refer to NOTE

60 - 95 psi

4.1 - 6.5 bar

Maximum Input Pressure

125 psi / 8.6 bar

Gas Flow (Cutting and Gouging)

300 - 500 scfh

142 - 235 lpm

!

WARNING

This torch is not to be used with oxygen (O

2

).

NOTE

Operating pressure varies with torch model,

operating amperage, and torch leads length.

Refer to gas pressure settings charts for each

model.

H. Direct Contact Hazard

For standoff tip the recommended standoff is 3/16

inches / 4.7 mm.

2T.04 Options And Accessories

For options and accessories, see section 6.

2T.05 Introduction to Plasma

A. Plasma Gas Flow

Plasma is a gas which has been heated to an ex-

tremely high temperature and ionized so that it

becomes electrically conductive. The plasma arc

cutting and gouging processes use this plasma to

transfer an electrical arc to the workpiece. The

metal to be cut or removed is melted by the heat

of the arc and then blown away.

While the goal of plasma arc cutting is separation

of the material, plasma arc gouging is used to re-

move metals to a controlled depth and width.

In a Plasma Cutting Torch a cool gas enters Zone

B, where a pilot arc between the electrode and the

torch tip heats and ionizes the gas. The main cut-

ting arc then transfers to the workpiece through

the column of plasma gas in Zone C.

A-00002

Workpiece

Power

Supply

+

_

C

B

A

Typical Torch Head Detail

By forcing the plasma gas and electric arc through

a small orifice, the torch delivers a high concentra-

tion of heat to a small area. The stiff, constricted

plasma arc is shown in Zone C. Direct current

(DC) straight polarity is used for plasma cutting,

as shown in the illustration.

Zone A channels a secondary gas that cools the

torch. This gas also assists the high velocity plasma

gas in blowing the molten metal out of the cut al-

lowing for a fast, slag - free cut.