beautypg.com

Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual

Page 59

background image

CUTMASTER 35mm, 40mm

Manual 0-5118 5-7 SERVICE

5. Remove the fitting from the filter element as-

sembly by inserting a 6 mm hex wrench into

the internal hex fitting and turning it counter

clock-wise (left). Numbers 4 and 5 in the previ-

ous illustration.

6. Disconnect the input line from the filter element

assembly.

7. Remove the filter element assembly through the

rear opening.

NOTE

If replacing or cleaning just the filter element

refer to the following illustration for disassembly.

Art # A-07990

Filter Element

8. Install the new or cleaned assembly by reversing

these procedures.

9. Turn ON the air supply and check for leaks

before reinstalling the cover.

Optional Single-Stage Filter Element

Replacement

These instructions apply to power supplies where the

optional Single-Stage Filter has been installed.

The Power Supply shuts down automatically when

the Filter Element becomes completely saturated. The

Filter Element can be removed from its housing, dried,

and reused. Allow 24 hours for Element to dry. Refer

to Section 6, Parts List, for replacement filter element

catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down system

before disassembling Filter to change Filter

Element.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-clock-

wise and remove it. The Filter Element is

located inside the Housing.

Art # A-02476

Filter

Element

(Cat. No. 9-7741)

Housing

Cover

Barbed

Fitting

Spring

Assembled Filter

O-ring

(Cat. No. 9-7743)

Optional Single-Stage Filter Element Replacement

5. Remove the Filter Element from the Housing

and set Element aside to dry.

6. Wipe inside of housing clean, then insert the

replacement Filter Element open side first.

7. Replace Housing on Cover.

8. Reattach gas supply.

NOTE

If unit leaks between housing and cover, inspect

the O-Ring for cuts or other damage.