beautypg.com

Section 4 system: operation, 01 front panel controls / features, Section 4 system: operation -1 – Tweco CutMaster 35mm 40mm User Manual

Page 29: Front panel controls / features -1, Cutmaster 35mm, 40mm

background image

CUTMASTER 35mm, 40mm

Manual 0-5118 4-1 OPERATION

SECTION 4 SYSTEM:

OPERATION

4.01 Front Panel Controls /

Features

See Illustration for numbering Identification

1. Output Current Control

Sets the desired output current. Output settings

up to 60 Amps may be used for drag cutting (with

the torch tip contacting the workpiece) or higher

for standoff cutting.

2. Function Control

Function Control Knob, Used to select between

the different operating modes.

SET

Used to purge the air through the unit

and torch and leads and to adjust gas pressure.

RUN

Used for general cutting operations

RAPID AUTO RESTART

Allows for faster

restarting of the Pilot Arc for uninterrupted cutting.

LATCH

Used for longer hand held

cuts. Once a cutting arc is established, the torch

switch can be released. The cutting arc will re-

main ON until the torch is lifted away from the

work piece, the torch leaves the edge of the work

piece the torch switch is activated again or if one

of the system interlocks is activated.

3. ON OFF Power Switch

ON / OFF

Switch controls input power to

the power supply. Up is ON, down is OFF.

4. Air/Gas Pressure Control

The Pressure

+

Control is used in the

"SET" mode to adjust the air/gas pressure. Pull

the knob out to adjust and push in to lock.

5.

AC Indicator

Steady light indicates power supply is ready for

operation. Blinking light indicates unit is in pro-

tective interlock mode. Shut unit OFF, shut OFF

or disconnect input power, correct the fault, and

restart the unit. Refer to Section 5 for details.

A

+

PSI

BAR

MAX

MAX

MIN

MIN

!

1

2

3

4

5 6 7 8 9

Art# A-07886

MIN

MAX

10

6.

Temp Indicator

Indicator is normally OFF. Indicator is ON when

internal temperature exceeds normal limits. Let

the unit cool before continuing operation.

7.

Gas Indicator

Indicator is ON when minimum input gas pressure

for power supply operation is present. Minimum

pressure for power supply operation is not suf-

ficient for torch operation.

8.

DC Indicator

Indicator is ON when DC output circuit is ac-

tive.

9.

!

Fault Error Indicator

Indicator is ON when Fault circuit is active. See

section 5 for explanations of fault lights.

10. Pressure Indicators

PSI

BAR

MAX

MAX

MIN

MIN

80
75
70
65

5.5

85

5.9

90

6.3

5.2
4.8
4.5

Art # A-08170

The Indicators will illuminate

according to the pressure set by the Pressure Con-