7fig. 4 — 50psd dimensional data – Carrier AQUAZONE PSV User Manual

Page 7

background image

7

Fig. 4 — 50PSD Dimensional Data

2' Service

Access

Air Coil Side

G

F

D

K

J

L

4

3

2

1

5

CAP

T

U

R

S

Air Coil

CSP

Front

Back

Front-View

BSP

Left Return Left View -

Air Coil Opening

Condensate
3/4” FPT

Left Return

Condensate
3/4” FPT

Right Return

5

1.1

1.6

T

U

S

Air Coil

Front

Back

Right Return Right View -

Air Coil Opening

R

ASP

Front

P

O

N

M

Blower

Opening

H

C

B

A

Front

P

O

N

Q

Blower

Opening

B

A

Right Return / Bottom Discharge

Left Return / Bottom Discharge

CSP

Isometric View

Condensate 3/4”

FPT

ASP

CSP

CAP

BSP

Standard Filter Bracket

2' Optional Service

Access Right Rtn

(left opposite)

ASP

E

Air Coil Side

1.6

Power Supply 3/4”

HV Knockout

1/2” Knockout

Low Voltage 1/2”

LV Knockout

NOTES:
1.

Condensate is

3

/

4

-in. FPT copper and is switchable from side to front.

2.

Vertical unit shipped with filter bracket only, extending from unit 2.5-in.
This bracket should be removed for return duct connection.

3.

Downflow unit does not have discharge flange, and is rated for zero
clearance installation.

4.

Shaded areas are recommended service areas, not required.

50PSD

UNIT

SIZE

OVERALL

CABINET

(in.)

WATER CONNECTIONS

(in.)

WATER

CONNEC-

TIONS (in.) -
UNITS WITH

HWR

ELECTRICAL
KNOCKOUTS

(in.)

DISCHARGE CONNECTION (in.)

DUCT FLANGE INSTALLED

(±0.10 in.)

RETURN

CONNECTION (in.)

USING RETURN

AIR OPENING

(±0.10 in.)

1

2

3

4

5

Loop

Water

FPT

HWG

FPT

1

2

J

1

/

2

Cond

K

1

/

2

Cond

L

3

/

4

Cond

M

(LH

rtrn)

N

O

Supply

Width

P

Supply

Depth

Q

(RH

rtrn)

R

S

Return

Depth

T

Return

Height

U

A

Width

B

Depth

C

Height

D

In

E

Out

F

HWG

In

G

HWG

Out

H

Conden-

sate

Loop

In D

Loop

Out E

Low

Voltage

Ext

Pump

Power

Supply

018

22.4

25.6

48.4

2.1 10.0

13.9

16.9

3.6

3

/

4

1

/

2

2.1

10.0

3.6

6.1

8.6

6.7

8.4

10.1

9.1

10.8

2.2

21.1

23.2

1.0

024,

030

22.4

25.6

52.5

2.1 10.0

13.9

16.9

3.6

3

/

4

1

/

2

5.96

13.13

3.6

6.1

8.6

6.7

8.4

10.1

9.1

10.8

2.2

21.1

27.2

1.0

036

25.4

30.6

54.5

3.4 10.8

15.6

18.9

3.6

3

/

4

1

/

2

5.96

13.13

3.6

6.1

8.6

7.2

9.0

13.4

12.9

10.4

2.2

26.1

27.2

1.0

042,

048

25.4

30.6

58.5

3.4 10.8

15.6

18.9

3.6

1

1

/

2

5.96

13.13

3.6

6.1

8.6

7.2

9.0

13.4

12.9

10.4

2.2

26.1

31.2

1.0

060,

070

25.4

30.6

62.5

3.4 10.8

15.6

18.9

3.6

1

1

/

2

5.96

13.13

3.6

6.1

8.6

7.2

9.0

13.4

12.9

10.4

2.2

26.1

35.2

1.0

PSC BLOWER AIRFLOW

CONFIGURATION

CODE

RETURN

DISCHARGE

L

Left

Bottom

R

Right

Bottom

LEGEND

ASP

Alternate Service Panel

BSP

Blower Service Panel

CAP

Control Access Panel

CSP

Compressor Service Panel

FPT

Female Pipe Thread

HWG — Hot Water Generator
HWR — Hot Water Reheat
LH

Left Hand

RH

Right Hand

a50-7846ef