tekmar 545 Thermostat Installation User Manual
Page 2

© 2008
D 545 - 07/08
2 of 40
Table of Contents
Table of Contents ............................................................2
Display and DIP Switches ..............................................2
Dip
Switches
...........................................................2
Access
Levels
.........................................................3
Display and Symbols Description............................3
User
Interface
.........................................................4
Setup ..............................................................................5
View
Menu
.............................................................5
Adjust
Menu
............................................................6
Time
Menu
............................................................ 13
Scene
Menu
.......................................................... 14
Schedule
Menu
..................................................... 16
Monitor
Menu
........................................................ 19
Test
Menu
............................................................ 21
Miscellaneous
Menu
............................................22
Testing .........................................................................23
Thermostat Operation .................................................. 24
Auxiliary Sensors ................................................. 24
Heat or Cool Mode of Operation ..........................25
Adjusting the Temperature ...................................25
Cycles Per Hour ...................................................26
Heating Terminal Units .........................................26
Heating
Operation
................................................27
Cooling
Operation
................................................29
Cool
Groups
.........................................................29
Fan
Operation
......................................................29
Filter Change ....................................................... 31
Time
Clock
........................................................... 31
Setting the Schedule ............................................. 31
Optimum Start / Stop ...........................................32
Scenes
.................................................................33
Away Hold ............................................................34
Radiant Base Load ..............................................34
Offset
...................................................................35
Warm Weather Shutdown ....................................35
Cold Weather Shutdown ......................................35
Units of Temperature ............................................35
Backlight
..............................................................35
tN4
Address
.........................................................35
Pump
Exercising
...................................................35
Error Messages ............................................................36
Cleaning the Thermostat ......................................39
Warranty .......................................................................40
Display and DIP Switches
Dip Switches
Y1 Rc G1 G1
R
C
tN4
S1
S2
Com
W1
Rh1
Rh2 W2
tN4 System Control (DIP Switch #2)
A tN4 System Control is a control, not a thermostat, that
the 545 thermostat connects to through the tN4 bus. All
tN4 compatible Outdoor Reset Modules are tN4 System
Controls.
•
• If the thermostat is connected to a tN4 System Control,
set the tN4 System Control DIP switch to tN4 System
Control (down position).
•
• If the thermostat is not connected to a tN4 System
Control, set the tN4 System Control DIP switch to None
(up position).
Lock / Unlock (DIP Switch #1)
Use the Lock / Unlock DIP switch to lock or unlock the
Access Level of the 545.
•
• To unlock the Access Level, set the DIP switch to the
unlocked (down) position.
•
• To lock the Access Level, set the DIP switch to the locked
(up) position. Once locked, a padlock is displayed in the
lower right corner of the display and the Access Level
cannot be changed.
Note: The tN4 System Control’s Lock / Unlock DIP switch
overrides the Lock / Unlock DIP switch on the 545. Set
the tN4 System Control’s Lock / Unlock DIP switch to the
Unlock position before Access Levels can be changed on
the thermostat.