Two-Stage Heating

-------------------------------------------------

-------------------------------------------------

Cooling Operation

Cooling is available when the Mode is set to Cool. The thermostat must be configured
for heat/cool/fan operation in order for the cooling operation to available.

To change the cool temperature setting, push the

or

button to select a preferred

temperature setting for the current schedule time period. The Cool On symbol is shown
on the display when the thermostat is cooling.

To change the temperatures for the other time periods, enter the Set Temp menu by
pressing both the

and

buttons together, press Menu to locate the Set Temp menu,

and press PRGM to enter the menu.

When operating a forced air cooling system, the thermostat uses a differential of +/-
0.7°F (0.4°C).

This operation is also recommended for rooms with hardwood floors. Setting floor
minimum and maximum temperatures is a way of enhancing the comfort of the living
space while protecting floor coverings.

The thermostat supports two-stage
heating. The second stage heat turns
on when the air temperature falls
below the Set Heat minus the W2
Differential setting and the W2 Delay
time expires. The second stage heat
turns off when the room temperature
reaches the Set Heat setting.

Set Heat Room

W1

Differential

W2

Differential

W2 On

W2 Off

W1 On

W1 Off

Freeze Protection

---------------------------------------------------

---------------------------------------------------

The thermostat operates the heat whenever the room temperature falls below 40°F
(4.5°C) even when the mode is set to off.