tekmar 521 Programmable Thermostat Installation User Manual

Page 16

background image

© 2014

521_D - 01/14

16 of 28

A Watts Water Technologies Company

Setting

Display

SET HEAT ROOM
Set the room heating temperature for the event.

Access Level: Installer, User

Range: 40 to 95°F (4.5 to 35.0°C)

Conditions: Room Sensor On or Sensor 1 or 2 is
set to Room.

Default: 70°F (21.0°C)

SET HEAT ROOM
Set the room heating temperature for the event.

Access Level: Installer, User

Range: 40 to 95°F (4.5 to 35.0°C)

Conditions: Room Sensor On or Sensor 1 or 2 is
set to Room and Schedule is set to On.

Default: 65°F (18.5°C)

SET COOL ROOM
Set the room cooling temperature for the event.

Access Level: Installer, User

Range: 50 to 100°F (10.0 to 38.0°C)

Conditions: Room Sensor On or Sensor 1 or 2 is
set to Room.

Default: 78°F (25.5°C)

SET COOL ROOM
Set the room cooling temperature for the event.

Access Level: Installer, User

Range: 50 to 100°F (10.0 to 38.0°C)

Conditions: Room Sensor On or Sensor 1 or 2 is
set to Room and Schedule is set to On.

Default: 85°F (29.5°C)

SET FLOOR
Set the floor heating temperature for the event.

Access Level: Installer, User

Range: OFF, 40 to 122°F
(OFF, 4.5 to 50.0°C)

Conditions: Sensor 1 or 2 is set to Floor.

Default: 72°F (22.0°C)

Set Temp Menu

Fan Menu

Setting

Display

FAN
Select if the fan should operate continuously (On)
or only together with the heating or cooling equip-
ment (Auto).

Access Level: Installer, User

Range: Auto or On

Conditions: Only available when FAN MODE is
not set to OFF and a room temperature sensor is
available.

Default: Auto