beautypg.com

tekmar 521 Programmable Thermostat Installation User Manual

Page 17

background image

© 2014

521_D - 01/14

17 of 28

A Watts Water Technologies Company

Time Menu

Setting

Display

MINUTES
Set the current time minutes.

Access Level: Installer, User

Range: 00 to 59

Conditions: Always available.

Default: 00

HOURS
Set the current time hours.

Access Level: Installer, User

Range: 12 AM to 11 PM or 00 to 23

Conditions: Always available.

Default: 12 AM

DAY OF WEEK
Select the current day of the week.

Access Level: Installer, User

Range: Sunday to Saturday

Conditions: Always available.

Default: Sunday

TIME MODE
Select either 12 or 24 hour time format.

Access Level: Installer, User

Range: 12 or 24 hour

Conditions: Always available.

Default: 12 hour

CLOCK
Select whether to show the time clock on the display.

Access Level: Installer, User

Range: OFF or ON

Conditions: The time is always shown when a sched-
ule is used and the clock setting option is hidden.

Default: OFF

Setting

Display

SET FLOOR
Set the floor heating temperature for the event.

Access Level: Installer, User

Range: OFF, 40 to 122°F
(OFF, 4.5 to 50.0°C)

Conditions: Sensor 1 or 2 is set to Floor and
Schedule is set to On.

Defaults
Air & floor sensors: 65°F (18.5°C)
Floor sensor only: OFF

SET FLOOR MAXIMUM
Set the maximum floor heating temperature.

MAX

Access Level: Installer

Range: 40 to 122°F, OFF
(4.5 to 50.0°C, OFF)

Conditions: Sensor 1 or 2 is set to Floor.

Default: 85°F (29.5°C)

Set Temp Menu