Machine Safety Switch: SI-LM40 Series Limit Switch Style

Periodic Checks

Safety switches should be checked at each shift change or machine setup by a

designated person (see below) for:
1. Breakage of the switch body or actuator,

2. Good alignment and full engagement of the actuator with the receptor,

3. Confirmation that the safety switch is not being used as an end stop,

4. Loosening of the switch or actuator mounting hardware, and

5. Verification that it is not possible to reach any hazard point through an opened guard

(or any opening) before hazardous machine motion has completely stopped.

In addition, a qualified person should check for the following on a periodic schedule,

determined by the user, based upon the severity of the operating environment and the

frequency of switch actuations:
1. Check the wiring chamber for signs of contamination.

2. Check the contacts for signs of deterioration or damage.

3. Inspect the electrical wiring for continuity and damage.

4. Verify that wiring conforms to the instructions on page 4 of this data sheet.
A designated person is identified in writing by the employer as being appropriately trained

to perform a specified checkout procedure. A qualified person possesses a recognized

degree or certificate or has extensive knowledge, training, and experience to be able to

solve problems relating to the safety switch installation (ANSI B30.2).

Repairs

Do not attempt any repairs to the switch. It contains no field-replaceable components.

Return the switch to the factory for warranty repair or replacement.
If it ever becomes necessary to return a switch to the factory, please do the following:
1. Contact the Banner applications engineering department at the number or address listed

on the back cover. They will attempt to troubleshoot the system from your description

of the problem. If they conclude that a component is defective, they will issue an RMA

(Return Merchandise Authorization) number for your paperwork, and give you the

proper shipping address.