beautypg.com

Specifications – Banner SureCross DX80 Wireless Networks User Manual

Page 6

background image

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

6

P/N 129323 rev. E

SureCross™ DX80K Wireless Configured

FlexPower™ Kit

General

Power*

Gateway and Node: +10 to 30V dc (For European applications: +10 to 24V dc, ± 10%)
FlexPower™ Node: +3.6 to 5.5V dc low power option

Power Consumption

Less than 1.4 W (60 mA) at 24V dc

Mounting

#10 or M5 (M5 hardware included)

M5 Fasteners Max. Tightening Torque

0.56 N•m (5 in•lbf)

Case Material

Polycarbonate

Weight

0.26 kg (0.57 lb.)

Indicators

Two LED, bi-color

Switches

Two Push Buttons

Display

Six Character LCD

External Cable Glands

Four PG-7 type, One 1/2-inch NPT type

Cable Glands Max. Tightening Torque

0.56 N•m (5 in•lbf)

* For European applications, power the DX80 from a Limited Power Source as defined in EN 60950-1.

Specifications

Radio

Range*

900 MHz: Up to 4.8 kilometers (3 miles)
2.4 GHz: Up to 3.2 kilometers (2 miles)

Transmit Power

900 MHz: 21 dBm Conducted
2.4 GHz: 18 dBm Conducted, ≤ 20 dBm EIRP

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

Antenna Connector

Ext. Reverse Polarity SMA, 50 Ohms

Antenna Max. Tightening Torque

0.45 N•m (4 in•lbf)

Link Timeout

64 seconds

* With the standard 2 dB antenna. High-gain antennas are available, but the range depends on the environment and line of sight. To determine the range of your wireless
network, perform a Site Survey.

Many parameters are configurable. The values in the tables represent factory defaults unless otherwise noted.

Inputs

Discrete Inputs

Two Sinking

Discrete Input Rating

3 mA max current at 30V dc

Discrete Input 1,2 Sample Rate

62.5 milliseconds

Discrete Input 1,2 Report Rates

On Change of State

Discrete Input ON Condition

Less than 0.7V

Discrete Input OFF Condition

Greater than 2V or Open

Analog Inputs

Two, 0 to 20 mA

Switched Power for Analog Input 1

15V

Analog 1 Sample Rate, Report Rate

15 minutes, 15 minutes (switch configurable)

Analog 2 Sample Rate

1 second

Analog 2 Report Rate

15 seconds or On Change of State (1% change in value)

Accuracy

0.1% of full scale +0.01% per ºC