Chapter 5

Maintenance

Safety Considerations

Preventive Maintenance

Note: Preventive maintenance is limited to cleaning the unit and connectors.

Cleaning

Front Panel

Clean the front panel face and meters with a soft cloth dampened with a mild detergent solution. Do not use an
excessive amount of water that would enter the unit and damage electrical components.
Line Section

Clean the line section connectors and elements with a dry cleaning solvent. Use a clean cloth to clean the mating
surfaces of the larger line sections and a cotton swab stick for the smaller connectors, elements, and line section ele-
ment socket. Clean all mating surfaces thoroughly, especially the bottom shoulder of the element socket and the
spring contact finger.

WARNING

Become thoroughly familiar with modern methods of resuscitation before working

near high voltage sources.

WARNING

Shock hazard. Always turn off AC power before removing any equipment panels.

WARNING

Disconnect this unit from AC power source before any disassembly for cleaning, repair

or replacement procedures. The potential for electrical shock exists.

WARNING

When using dry cleaning solvents, provide adequate ventilation and observe normal

safety precautions. Many dry cleaning agents emit toxic fumes that may be harmful to

your health if inhaled.

CAUTION

Do not bend this contact finger when cleaning. The position of this contact is some what

critical. If it is out too far the element will not enter the socket and if it is in too far, it will not

make contact with the button on the element. For contact adjustments, refer to "Adjusting

the Element Wiper Contact" on page 18.